Leaks Around Solar Mounts: Tracing a Roof Leak Under Solar Panels

A solar panel roof leak, in short

A solar panel roof leak is almost never a leak in the panels. Panels are not part of the roof’s waterproofing, so water that reaches the inside of the house has come through the roof itself, usually at a mount, a disturbed flashing, a cracked tile or an ageing layer beneath the covering.

What makes these leaks frustrating is access. The likely source sits under the array, hidden from view and awkward to reach, and water can travel some distance along the underlayment or a rafter before it appears on a ceiling. The stain is rarely directly below the cause.

This article explains where leaks under solar arrays usually start, why they are hard to trace, what to do when one appears, and who handles which part of the fix. We work on the roof side. Removing and refitting panels, when that is needed, is the solar company’s work.

Panels are not the waterproofing

A panel sits on rails above the roof surface. Rain falls on the panel, runs off its lower edge, and lands on the roof beneath, which then sheds it as it would anyway. The panel does not seal anything and cannot leak into the house by itself.

What connects the array to the building is a set of mounts, each fixed through the roofing to the structure. Every mount is a penetration through the waterproofing layer, sealed by a flashing and often a sealant. Those penetrations are where the roof’s integrity depends on the solar installation.

Conduit and wiring add more. Where cables pass into the building through the roof, that entry point is another penetration that has to be flashed and sealed.

So the question when water appears is not what is wrong with the panels. It is which penetration, or which part of the roof around them, has let water through.

Where leaks under an array usually start

The most common source is a mount whose flashing was not installed correctly, or which relies on sealant that has aged and cracked. A flashing should shed water over and around the penetration. Sealant alone is a short-term seal in this sun.

The second is disturbed roofing. On tile, cracked or displaced tiles around mounts let water reach the underlayment. On shingle, lifted or damaged shingles around mounts expose the layer beneath. Installation crews walking the roof can cause damage away from the mounts too.

The third is the roof itself. An underlayment that was already old when the array went on can fail beneath it, and the leak then looks like a solar problem when the array is only the bystander.

Debris is the fourth. Leaves, nesting material and dust collect under panels and can dam water against mounts or block drainage paths.

Heat ages the seals around mounts

At the Scottsdale Municipal Airport weather station, NOAA’s 1991 to 2020 normals average about 93 days a year at or above 100 degrees Fahrenheit and about 161 days at or above 90 (NOAA NCEI). Sealants, rubber boots and gaskets age quickly at those temperatures.

That means a mount sealed only with sealant can be watertight when installed and leaking a few summers later. The panel above it gives some shade, but the edges and exposed parts of the seal still see sun and heat, and the roof moves through every hot day and cooler night.

A City of Scottsdale homeowner guide describes heat in the attic expanding and contracting the roof structure and working nails loose over time. Mount fixings experience the same movement, which can loosen them or open gaps in their seals.

Properly flashed mounts rely less on sealant and age better for that reason.

Monsoon storms reveal what was already failing

The National Weather Service office in Phoenix defines the monsoon season as June 15 through September 30 and names damaging winds and torrential rainfall among its hazards (NWS Phoenix). Most leaks under arrays show themselves in that season, often in the first heavy storm after months of dry weather.

Wind-driven rain is the test. It pushes water sideways and upward into gaps that ordinary rain would pass over, and it hits the roof hardest at its edges and around anything that protrudes. A mount with a marginal seal may stay dry in winter rain and leak in the first monsoon storm.

The NOAA Storm Events Database records 659 thunderstorm wind reports in Maricopa County between 2016 and 2025 (NOAA NCEI). Those are reports rather than every event, but they show how often the roof faces that test.

A leak that appears only in storms, and only in certain wind directions, often points to a penetration on the side the storm came from.

Water travels before it shows up

Water that gets past a roof covering rarely drops straight down. It runs along the underlayment, follows rafters, collects on top of ceiling materials and appears wherever it finally finds a way through. On a roof with an array, that can be well away from the mount that let it in.

That is why a stain under one corner of the array does not prove the leak is at that corner. It may be, or the water may have travelled from a mount further up the slope. Tracing it means following the path back, from the attic where possible and from the roof.

Stains that appear in more than one place after the same storm may point to more than one source, or to an ageing layer beneath the covering rather than a single penetration.

Photographs of each stain, with the date and the weather, help whoever traces the leak. So does knowing roughly where the mounts sit, which the solar company’s installation drawings usually show. Matching a stain to the nearest mounts uphill of it narrows the search before anyone goes onto the roof.

First steps when a leak appears

Contain the water inside first: move belongings, use containers, and keep electrical items away from any wet ceiling. Photograph the stain and any visible water, and note when it appeared and what the weather was doing. Those notes become the starting point for whoever traces the leak.

If it is safe, look in the attic for wet patches on the underside of the deck and follow them uphill towards the source. Do not go onto the roof. Moving around an array is awkward and dangerous, especially on tile, and the City of Scottsdale homeowner guide says roof work can be dangerous and lethal for the inexperienced.

Check whether the solar installation is still under a workmanship warranty that covers penetrations, and contact the installer if it is. Then have the roof side assessed, ideally by someone who can tell a mount problem from a roof problem.

If you may claim on insurance, contact your insurer before repairs.

Who handles which part of the fix

A leak at a mount involves two trades. The roof side, meaning the flashing, the roofing around the mount and the waterproofing layer beneath, is roofing work. The array itself, including removing, storing and refitting panels where access requires it, is solar work and belongs to the solar company.

Some mount leaks can be reached and repaired without removing panels. Others cannot, because the mount sits under the middle of the array. In those cases the solar company has to take the affected panels off before the roof-side repair can be made, and refit them afterwards.

Our solar-ready roofing in Scottsdale page covers the roof-side work, including flashing at mount penetrations. We do not remove, store or refit panels, and we coordinate with the solar company when they need to come off.

Flashing leaks more generally, away from solar, are covered in our article on roof flashing leaks.

Insurance and leaks under solar

The 2015 Arizona Department of Insurance guidance notes that interior rain damage may not be covered unless the rain entered through a roof or wall damaged by wind or hail (Arizona Department of Insurance). A leak from an aged sealant or poor installation may not meet that test.

That makes the cause important. Storm damage to the roof around an array is a different matter from a mount that was never flashed properly. The same guidance advises documenting damage and contacting the insurer before repairs, and notes that mold and rot from water damage are typically excluded.

That document dates from 2015, and policies vary. Confirm with your own insurer what your policy covers.

If the leak traces to the installation, the installer’s workmanship warranty may be the more relevant route.

Preventing the next leak

The surest prevention is at installation: a sound roof with enough remaining life, mounts that are properly flashed rather than relying on sealant, careful handling of tile, and before-and-after photographs. The questions to settle before an array goes on are covered in solar panels on a tile roof.

Once an array is up, the practical measures are watching ceilings below it after storms, keeping debris from building up under panels, and having the roof around the array looked at periodically, especially before the monsoon.

Whether panels harm a roof at all is a broader question, covered in do solar panels damage your roof. The wider context is in the solar and flat roof guide.

A leak traced and fixed properly once is far cheaper than a ceiling repaired after every storm.

Where to start

When a stain appears under an array, record it, contain the water, and look in the attic if it is safe. Check the solar installer’s warranty terms and contact them if they apply. Then have the roof side assessed so the actual source is found rather than guessed.

One safety point. Arrays make roofs harder and more dangerous to move around on, and the City of Scottsdale’s homeowner guide says roof work can be dangerous and lethal for the inexperienced. If you would rather have someone look at the roof side, Residential Roofing Scottsdale works across Scottsdale and the surrounding Valley. Call (480) 919-1173.

Frequently asked questions

These are the questions homeowners in this area ask most often when a ceiling stain appears below a solar array, usually after the first heavy storm of the monsoon. Each answer is kept deliberately short and covers the roof side only, because the panels themselves are the solar company’s responsibility.

Can solar panels cause a roof leak?

The panels themselves do not, because they are not part of the waterproofing. The mounts that hold them pass through the roof, and a poorly flashed or ageing mount seal, or roofing damaged during installation, can let water in.

How do you find a leak under solar panels?

Start from the stain and follow the water path back, from the attic where possible and then from the roof. Water often travels along the underlayment or rafters, so the source can be some distance from the stain.

Do solar panels have to be removed to fix a roof leak?

Not always. Some mounts can be reached and repaired with the panels in place. Mounts under the middle of an array usually need the affected panels taken off first, which is the solar company’s work.

Who is responsible for a leak around solar mounts?

It depends on the cause and the contracts. A leak from installation may fall under the solar installer’s workmanship warranty. A failing roof beneath the array is a roofing matter. Check the warranty terms first.

Does insurance cover a leak under solar panels?

The 2015 Arizona Department of Insurance guidance says interior rain damage may not be covered unless rain entered through a roof damaged by wind or hail. Policies vary, so confirm with your own insurer.

How can leaks around solar mounts be prevented?

Mounts should be properly flashed rather than relying on sealant, tile around them handled carefully, and the roof sound before the array goes on. Afterwards, watch ceilings after storms and keep debris from building up under the panels.